Uncemented Hip System
XL - Axenture Stem
The XL-Axenture Stem capitalizes on the excellent clinical results of proximal to distal tapered stem designs. The XL-AXENTURE system features a variety of stem designs that provide different methods of stem fixation, bone geometries and that also addresses different patients.
The porous-coated design promotes bone ingrowth and 3-dimensional interlocking between the implant and the bone. All XL-AXENTURE femoral stems are made from high-strength, titanium and feature a 3° proximal to distal taper. Parallel and longitudinally arranged flutes on the stems provide good axial and Anti-Rotational stability. The circulotrapezoidal neck of XL-AXENTURE stems is smaller in the anterior/ posterior direction than most comparative stems.
- XL-AXENTURE cementless femoral stems are available in 7 different sizes. All are available in standard and high offset versions.
- All stems in the XL-AXENTURE system are implanted with one simple set of surgical instruments.
- The 12/14 taper of XL-AXENTURE stems accepts 28, 32 and 36mm femoral heads in a variety of neck lengths.
- Dual Porous Coating Porous Titanium layer provided enhanced primary and secondary fixation. With the application of a second layer of HaP we can have an additional enhancement of secondary implant fixation, with a rapid bone ingrowth. Ti Porous 400 ±50, Hap 90±30.
XYLS Revision Stem
Ref. No | Stem Size |
---|---|
5005-00-0S | 0S |
5005-00-0L | 0L |
5005-00-01 | 01 |
5005-00-02 | 02 |
5005-00-03 | 03 |
5005-00-04 | 04 |
5005-00-05 | 05 |
CEMENTLESS STEM
- Suits All forms of Bone Anatomy.
- No Turning moment and calcar absorption as the stem is
collarless. - Tapered stem leads to excellent radial compressive loading
& reduces shear forces. - Available in single, clearly labeled sterile pack.
Resurge Stem
The XL-Resurge Revision Stem is made of Titanium Medical Grade 5 ELI, whose biocompatibility has been proven by numerous histological studies of implant retrievals. The rough-blasted surface supports bone formation and, thus, generates reliable secondary stability. The characteristic narrow ribs on the XL-Resurge Revision Stem allows bone formation as well: the longitudinal furrows between the ribs provide room for the vessels in the marrow cavities to
regenerate. This is an effective prerequisite for reactive ossification and revascularization in the cortex. A fundamental advantage of Titanium Medical Grade 5 ELI is its modulus of elasticity, which can have particularly positive effects in revision surgery. This element is designed to fulfill a biomechanical role, in that it allows visible bone regeneration in the proximal femoral segment. The synergetic interaction between material, surface structure, and design of the XL-Resurge Revision Stem create idea conditions that allow bone formation.
Ref. No | Stem Size |
---|---|
1007-RE-13-190 | 13mm x 190mm |
1007-RE-13-230 | 13mm x 230mm |
1007-RE-13-260(L) | 13mm x 260mm(Left) |
1007-RE-13-260(R) | 13mm x 260mm(Right) |
1007-RE-14-190 | 14mm x 190mm |
1007-RE-14-230 | 14mm x 230mm |
1007-RE-14-260(L) | 14mm x 260mm(Left) |
1007-RE-14-260(R) | 14mm x 260mm(Right) |
1007-RE-15-190 | 15mm x 190mm |
1007-RE-15-230 | 15mm x 230mm |
1007-RE-15-260(L) | 15mm x 260mm(Left) |
1007-RE-15-260(R) | 15mm x 260mm(Right) |
1007-RE-16-190 | 16mm x 190mm |
1007-RE-16-230 | 16mm x 230mm |
1007-RE-16-260(L) | 16mm x 260mm(Left) |
1007-RE-16-260(R) | 16mm x 260mm(Right) |
1007-RE-17-190 | 17mm x 190mm |
1007-RE-17-230 | 17mm x 230mm |
1007-RE-17-260(L) | 17mm x 260mm(Left) |
1007-RE-17-260(R) | 17mm x 260mm(Right) |
- Modular revision endoprosthesis with straight and
curved stems - Rotational stability through star shape and distal
interlocking option - Catch-free stability by applied frictional connection
- Multiple opportunities for trial reduction
- Intra- and extraosseous assembly of the implant
components
XL - Axenture Cup
Resurge Cup
- Titanium acetabular shell with Dual Porous Coating
- Incorporates three screw holes in one quadrant to offer
additional implant stability - Available in sizes 44mm to 60mm
- Indicated for cementless biological fixation
Titanium | Stailness Steel | Head(Ømm) |
---|---|---|
1006-0T-44 | 1006-0S-44 | 44 |
1006-0T-46 | 1006-0S-46 | 46 |
2006-0T-48 | 2006-0S-48 | 48 |
2006-0T-50 | 2006-0S-50 | 50 |
2006-0T-52 | 2006-0S-52 | 52 |
2006-0T-54 | 2006-0S-54 | 54 |
2006-0T-56 | 2006-0S-56 | 56 |
2006-0T-58 | 2006-0S-58 | 58 |
2006-0T-60 | 2006-0S-60 | 60 |
Standard Cup
- Titanium acetabular shell with Dual Porous Coating
- No screw-holes
- Available in sizes 44mm to 60mm
- Indicated for cementless biological fixation
Ref No. | Head (Ømm) |
---|---|
1006-FC-44 | 44 |
1006-FC-46 | 46 |
1006-FC-48 | 48 |
1006-FC-50 | 50 |
1006-FC-52 | 52 |
1006-FC-54 | 54 |
1006-FC-56 | 56 |
1006-FC-58 | 58 |
1006-FC-60 | 60 |
XL - Axenture Cup
Spiked Cup
- Titanium acetabular shell with Dual Porous Coating
- Incorporates three porous-coated spikes to maximize
implant stability and rotational control - Available in sizes 44mm to 60mm
- Indicated for cementless biological fixation
Ref No. | Head (Ømm) |
---|---|
1006-SC-44 | 44 |
1006-SC-46 | 46 |
1006-SC-48 | 48 |
1006-SC-50 | 50 |
1006-SC-52 | 52 |
1006-SC-54 | 54 |
1006-SC-56 | 56 |
1006-SC-58 | 58 |
1006-SC-60 | 60 |
Multihole Cup
- Titanium acetabular shell with Dual Porous Coating
- Incorporates eight to 12 screw holes, depending on
- cup size, to maximize implant stability and provide
screw position flexibility - Indicated for cementless biological fixation
Ref No. | Head (Ømm) |
---|---|
1006-MH-44 | 44 |
1006-MH-46 | 46 |
1006-MH-48 | 48 |
1006-MH-50 | 50 |
1006-MH-52 | 52 |
1006-FC-54 | 54 |
1006-MH-54 | 54 |
1006-MH-56 | 56 |
1006-MH-58 | 58 |
1006-MH-60 | 60 |
XL - Axenture Liner
Acetabular liners for the AXENTURE System are available in two types of polyethylene – our high-performing compression-moulded
standard polyethylene and Crosslinked Polyethylene as per ASTM F-648 and ISO 5834-2 .
Neutral Liner
- Provides 180 degree coverage of the femoral head
- Offers a symmetric face about the metal shell rim
- Available in sizes 44mm to 60mm
- Typical range of motion (using 28mm +5 Head and Stem):
Ref No. | Head (Ømm) | Femoral Head (Ømm) |
---|---|---|
1006-NL-28-44 | 44 | 28 |
1006-NL-28-46 | 46 | 28 |
1006-NL-28-48 | 48 | 28 |
1006-NL-32-50 | 50 | 32 |
1006-NL-32-52 | 52 | 32 |
1006-NL-32-54 | 54 | 32 |
1006-NL-36-54 | 54 | 36 |
1006-NL-36-56 | 56 | 36 |
1006-NL-36-58 | 58 | 36 |
1006-NL-36-60 | 60 | 36 |
+4 Neutral Liner
- Provides 180 degree coverage of the femoral head
- Offers a symetrical face about the metal shell rim
- Lateralizes head center 4mm
- Typical range of motion: 124° Medial/Lateral, 124° Anterior/Posterior
Ref No. | Head (Ømm) | Femoral Head (Ømm) |
---|---|---|
1006-NL-7-28-44 | 44 | 28 |
1006-NL-7-28-46 | 46 | 28 |
1006-NL-7-28-48 | 48 | 28 |
1006-NL-7-32-50 | 50 | 32 |
1006-NL-7-32-52 | 52 | 32 |
1006-NL-7-32-54 | 54 | 32 |
1006-NL-7-36-54 | 54 | 36 |
1006-NL-7-36-56 | 56 | 36 |
1006-NL-7-36-58 | 58 | 36 |
1006-NL-7-36-60 | 60 | 36 |
20 Degree Face Changing/Hooded Liner
- Provides 180 degree coverage of the femoral head plus a
5mm build-up to address dislocation - Depending on placement, offers 20 degrees of anteversion/
retroversion and/or 20 degrees of abduction/adduction - Typical range of motion: 107° Medial/Lateral 122° Anterior/Posterior
Ref No. | Head (Ømm) | Femoral Head (Ømm) |
---|---|---|
1006-20-28-44 | 44 | 28 |
1006-20-28-46 | 46 | 28 |
1006-20-28-48 | 48 | 28 |
1006-20-32-50 | 50 | 32 |
1006-20-32-52 | 52 | 32 |
1006-20-32-54 | 54 | 32 |
1006-20-36-54 | 54 | 36 |
1006-20-36-56 | 56 | 36 |
1006-20-36-58 | 58 | 36 |
1006-20-36-60 | 60 | 36 |
10 Degree Face Changing Liner
- Provides 180 degree coverage of the femoral head
- Depending upon placement, changes orientation
(anteversion, retroversion, abduction, adduction) by 10 degrees - Typical range of motion: 113° Medial/Lateral, 113° Anterior/Posterior
Ref No. | Head (Ømm) | HFemoral Head (Ømm) |
---|---|---|
1006-28-44 | 44 | 28 |
1006-28-46 | 46 | 28 |
2006-28-48 | 48 | 28 |
2006-32-50 | 50 | 32 |
2006-32-52 | 52 | 32 |
2006-32-54 | 54 | 32 |
2006-36-54 | 54 | 36 |
2006-36-56 | 56 | 36 | 2006-36-58 | 58 | 36 | 2006-36-60 | 60 | 36 |
Ball Liner
Femoral Head
- Unique machining techniques, guarantee perfect roundness and excellent polish.
- 100% Quality Assurance of all ball spheres assure longevity of implant in the human body.
- 100% Quality Control of 12/14 taper comes make them synergise with similar tapered stems worldwide.
- The captive head ensures continuous internal articulation, ease of assembly / disassembly and full prosthetic security.
Ref No. | Head(Ømm) | Head Neck |
---|---|---|
5006-00-24/-3 | 24 | -3 |
5006-00-28/-3 | 28 | -3 |
5006-00-28/-3 | 32 | -3 |
5006-00-28/-3 | 38 | -3 |
5006-00-24/0 | 24 | 0 |
5006-00-28/0 | 28 | 0 |
5006-00-28/0 | 32 | 0 |
5006-00-28/0 | 38 | 0 |
5006-00-24/+4 | 24 | +4 |
5006-00-28/+4 | 28 | +4 |
5006-00-28/+4 | 32 | +4 |
5006-00-28/+4 | 38 | +4 |
5006-00-24/+7.5 | 24 | +7.5 |
5006-00-28/+7.5 | 28 | +7.5 |
5006-00-28/+7.5 | 32 | +7.5 |
5006-00-28/+7.5 | 38 | +7.5 |
Cancellous Screws
- For the improved XL-Axenture wall thickness special fixation screws with flatter screw heads have been designed.
- The self-cutting, 6.5 mm screws are inserted with a 3.5 hex screwdriver and allow a pivoting angle of +/- 9°.
Ref. No | Length(mm) |
---|---|
1009-0T-25 | 25 |
1009-0T-30 | 30 |
1009-0T-35 | 35 |
1009-0T-40 | 40 |
1009-0T-45 | 45 |
1009-0T-50 | 50 |